Description

The 192962C-01 NI PXI-2584 12-Channel 600V CAT II Multiplexer by National Instruments is a high-voltage PXI Multiplexer Switch Module ideal for a variety of applications, featuring reed relays with quick actuation times. With a switch bandwidth of 900 kHz, this module can route general-purpose ATE loads or high-voltage, low-current signals, making it suitable for fuel cell and battery stack applications.

The 192962C-01 NI PXI-2584 12-Channel 600V CAT II Multiplexer by National Instruments is a high-voltage PXI Multiplexer Switch Module designed for a variety of applications. This module features reed relays with quick actuation times and a long mechanical relay life, making it ideal for completing measurements on multiple channels. It offers various topologies such as a 1-wire 12 × 1 multiplexer, 2-wire 6 × 1 multiplexer, 1-wire dual 6 × 1 multiplexers, and a 2-wire 11 × 1 interleaved multiplexer. With a switch bandwidth of 900 kHz, the PXI-2584 can route general-purpose ATE loads or high-voltage, low-current signals and has 600 V CAT I channel-to-ground isolation. This module can withstand less than or equal to 2,500 V surge voltage and provide 10 Watts switching power and 0.5 A carry or switching current per channel. The PXI-2584 has a CAT II certification at 300 V and is suitable for fuel cell and battery stack applications. It incorporates reed relays with a rhodium relay contact material and utilizes PXI trigger lines <0...7>. This efficient module consumes only 1.6 W at 5 V and measures 8.5 x 0.8 x 5.1 in. in physical dimensions, weighing 7.5 oz. Operating at a recommended temperature range of 0 °C to 55 °C, the PXI-2584 offers a maximum scan rate of 600 channels/s and is designed for easy relay functions and debugging switch code execution.

Made By National Instruments
Part Number 192962C-01 / 778572-84
Configuration 12-Channel Multiplexer with various topology options (1-wire, 2-wire)
Voltage & Safety Rating 600V CAT II / 300 V CAT II, 600 V CAT I channel-to-ground isolation
Relay specifications Reed relays, 0.4 ms operating time, 3 imes 10^8 cycle life
Switching & Current 10 Watts, 0.5 A carry or switching current, 600 channels/s scan rate

Distribution Cache Shipping Info and Options

Shipping Carriers: Here at Distribution Cache we ship using UPS, FedEx, DHL, or TNT. In most cases we get very competitive rates based on our volume and will be happy quote shipping cost to your location upon request. We also know that many customers would prefer to ship collect on their own account numbers and welcome this option.

Shipping Blind: We recognize that many of our customers intend to re-sell the product to their end user. We respect our customer’s relationships with their clients and offer blind shipping as an option to ensure that the package arrives in the most clandestine way possible.

Shipping Process: We take pride in the way we package your order and spare no cost in making sure that it arrives safely at your facility. In the case of new parts, we are always sure to package the factory box inside another larger box for safe transit. For reconditioned parts we often use Distribution Cache customized packaging that is specially made to protect the products from the bumps and falls present during shipment.

 

Shipping Options:

Next Day Air Early AM - This service is the fastest overnight delivery option available. For most locations the package will be guaranteed by 8:30AM.

Next Day Air – This service guarantees delivery by 10:30AM and is the most frequently used option for overnight shipments.

Next Day Air Saver – This cost saving overnight alternative guarantees delivery by 3PM the next day.

2nd Day Air – For domestic shipments that would take 3-5 days if shipped via Ground, sometimes having the order in 2 days is a great way to go

Ground – Ground is the most inexpensive shipping option provided. Please ask if we are doing a “free domestic ground” shipping promotion on your order. We often provide free ground shipping on larger orders.

 

Emergency Courier – At times we can help work with a courier service to get the part to your facility during downtimes scenarios. We prefer that the customer sets up the courier but we can be there to make sure the product is handed off to the driver. Please give us a call to see if this is an option on your order.

Please Note: Products listed as “ships today” can ship same-day if an order is placed before 4PM. For larger drives and motors we ask that notification for same-day shipments be provided by 2PM at the latest. For any products listed as “ships in 3-5 days”, please give us a call to see if this can be expedited.

Question:

What types of applications is the NI PXI-2584 12-Channel 600V CAT II Multiplexer suitable for?

Answer:

The NI PXI-2584 12-Channel 600V CAT II Multiplexer is suitable for a variety of applications where high-voltage and multiple channel measurements are required. This includes general-purpose ATE loads and applications that involve high-voltage, low-current signals such as fuel cell and battery stack applications.

Question:

What are some of the topologies offered by the PXI-2584?

Answer:

The PXI-2584 offers various topologies, including a 1-wire 12 imes 1 multiplexer, 2-wire 6 imes 1 multiplexer, 1-wire dual 6 imes 1 multiplexers, and a 2-wire 11 imes 1 interleaved multiplexer.

Question:

What is the maximum voltage and current specifications for a channel on the PXI-2584?

Answer:

The PXI-2584 module can handle 600 V CAT I channel-to-ground isolation and withstand less than or equal to 2,500 V surge voltage. It also provides 10 Watts switching power and 0.5 A carry or switching current per channel.

Question:

What type of relay contact material does the PXI-2584 use and how does it affect the module's performance?

Answer:

The PXI-2584 utilizes rhodium relay contact material for its reed relays, which contributes to the module's quick actuation times and long mechanical relay life, enhancing the reliability and efficiency in applications requiring frequent switching.

Question:

What are the power consumption and physical characteristics of the PXI-2584 module?

Answer:

The PXI-2584 module consumes 1.6 W at 5 V and has physical dimensions of 8.5 x 0.8 x 5.1 inches, with a weight of 7.5 oz.