BL2-D15A

by

Okuma BLII-D-series

BL2-D15A has a power unit capacity of 15 with a special function rating A

BL2-D15A Image 1 BL2-D15A Image 2 BL2-D15A Image 3
BL2-D15A Image 1
 

Technical Specs:
Series:BL2-D or BLII-D
Power unit capacity:15
Special Function:A

Stock Level:

Call

Shipping:

Information:

We do our best to stock both
New and Reconditioned Surplus

Contact Info:

Phone: 1-919-443-0207
Email: sales@wakeindustrial.com

Check Out Our Repair Page
Warranty
Worldwide Shipping
Payment Options

Exchange Program:
We would like to offer an upfront discount on your purchase with the return of your defective unit to us. We value the opportunity to repair your defective unit in order to keep our stock shelves full for other customers. Please ask today and we will provide the maximum discount we can offer for that given part. We can even send a shipping label in the box for the return.

 
BL2-D15A has a power unit capacity of 15 with a special function rating A. The type A unit is a brushless motor driving unit which controls current to it’s brushless motor according to the commands being sent from the servo processor. BL2-D15A features a supplying command current, no added need for exteranl circuits, indicating alarms and LEDs, and a dynamic brake funcation.

 What is a BDII-D?

The BLII-D type A unit, is a brushless motor driving unit. The BLII-D type A controls current to the brushless motor according to the current commands sent from the servo processor board (SVP IID).

Features:

Supplying commanded current to the motor in PWM method by IGBT.

Eliminating the necessity for adding external circuits thanks to the built-in circuit for discharging regenerative energy.

Indicating alarm with LEDs while transferring alarm data to SVP IID by two-way communication function.

Braking the motor by DB (dynamic brake) function.

 

Protecting the motor from overcurrent, overvoltage and overload.  Enabling compact design by addition of 2-axis unit to BL II-D series. Reducing wiring part by adoption of highly reliable large-current PC board.

Distribution Cache Shipping Info and Options

Shipping Carriers: Here at Distribution Cache we ship using UPS, FedEx, DHL, or TNT. In most cases we get very competitive rates based on our volume and will be happy quote shipping cost to your location upon request. We also know that many customers would prefer to ship collect on their own account numbers and welcome this option.

Shipping Blind: We recognize that many of our customers intend to re-sell the product to their end user. We respect our customer’s relationships with their clients and offer blind shipping as an option to ensure that the package arrives in the most clandestine way possible.

Shipping Process: We take pride in the way we package your order and spare no cost in making sure that it arrives safely at your facility. In the case of new parts, we are always sure to package the factory box inside another larger box for safe transit. For reconditioned parts we often use Distribution Cache customized packaging that is specially made to protect the products from the bumps and falls present during shipment.

 

Shipping Options:

Next Day Air Early AM - This service is the fastest overnight delivery option available. For most locations the package will be guaranteed by 8:30AM.

Next Day Air – This service guarantees delivery by 10:30AM and is the most frequently used option for overnight shipments.

Next Day Air Saver – This cost saving overnight alternative guarantees delivery by 3PM the next day.

2nd Day Air – For domestic shipments that would take 3-5 days if shipped via Ground, sometimes having the order in 2 days is a great way to go

Ground – Ground is the most inexpensive shipping option provided. Please ask if we are doing a “free domestic ground” shipping promotion on your order. We often provide free ground shipping on larger orders.

 

Emergency Courier – At times we can help work with a courier service to get the part to your facility during downtimes scenarios. We prefer that the customer sets up the courier but we can be there to make sure the product is handed off to the driver. Please give us a call to see if this is an option on your order.

Please Note: Products listed as “ships today” can ship same-day if an order is placed before 4PM. For larger drives and motors we ask that notification for same-day shipments be provided by 2PM at the latest. For any products listed as “ships in 3-5 days”, please give us a call to see if this can be expedited.

Unit Configuration

Order No. Name
A006-0600 SVC II BOARD 1-axis
A006-0601 SVC II BOARD 2-axis
.A.006-0610 BLII -D15A P.U
.11.006;0611 BLII-D30A P.U
Jl.006-0612 BLII -D50A P.U
Jl.006-0613 BLII-D75A P.U
A006-0614 BLII -D100A P.U
A006-0615 BLII -D150A P.U
11006-0620 BLII -D1515A P.U
11006-0621 BLII-D3015A P.U
J006-0622 BLII -D5015A P.U
J006-0623 BLII-D7515A P.U
J006-0624  
   
   
J006-0625 BLII-D3030A P.U
Jl.006-0626 BLII-D5030A P.U
Jl.006-0627 BLII-D7530A P.U
A006-0628  
   
   
A006-0629 BLII-D5050A P.U
A006-0630 BLII-D7550A P.U
A006-0631  
   
   
A006-0632 BLII-D7575A P.U
A006-0644 ("1) BLII-D100AS P.U
A006-0645 ,1) BLII-D150AS P.U

 

Applicable Motor List

Unit Capacity Motor Output (kW)   Motor Type
15 Up to 0.8   BL-MH1OE-20, BL-MS1OE-30, BL-MH20E-20
30 0.8 to 1.5   BL-MH51E-20, BL-MS50E-20, BL-MH101E-12
50 1.5 to 2.5   BL-MH101E-20, BL-MS50E-30, BL-MH201E-12, BL-MS75E-20
BL-MS75E-30      
75 2.5 to 4.0   BL-MH201E-20, BL-MH101E-30, BL-MS125E-20, BL-MH301 E-12
       
BL-MS125E-30      
100 4.0 to 6.0   BL-MH401E-12, (BL-MH301E-20), (BL-MH201E-30)
150 4.0 to 8.0   BL-MH301E-20, BL-MH201E-30, BL-MS125E-60, BL-MH?OOE-10, BL-MH101E-60, BL-MS140E-30

 

Protective and Abnormality Detecting

  Function Purpose/Content
1 Protection from ground fault The circuit protector shuts off the power the moment ground fault occurs inside the servo amplifier or the motor.
2 Protection of control power source from overcurrent The 3.2 A fuse is blown by the overcurrent from the power circuit caused by control circuit failure. Power is thus shut off immediately.
3 Motor transient overcurrent (OCM) When a large current exceeding 150 % of the limit value flows into the motor, an alarm occurs to prevent breakage of main circuit elements and motor demagnetization.
4 Short-drcuit in DC power source (OCS) When the inverter DC power is shorted because of the trouble in main circuit elements or control circuit, or when an overcurrent flows because of ground fault inside the motor, an alarm occurs to prevent secondary breakage of the main circuit elements.
5 Abnormally high voltage (OV) If the inverter DC power voltage increases to an abnormally high level, an alarm occurs to prevent breakage of the main circuit elements.
6 Abnormally low voltage (UV) If the inverter DC power voltage decreases to an abnormally low level, an alarm occurs to prevent unstable operation of the motor.
7 Reger,erative energy discharge resistance overheat (ROH) If the regenerative energy discharge resistances pass the current continuously or is overheated by excessive regenerative energy, an alarm occurs to prevent burning of the resistances.
8 Power board overheat (BOH) If the power board is overheated by the trouble in main circuit elements or control circuit, an alarm occurs to prevent burning of the board.
9 Abnormal power in control circuit (LOSS) If the control circuit voltage exceeds the safety operation range because of circuit failure, an alarm occurs to prevent malfunction of the circuit.

BL2-D15A

Main Image

Secondary Image

BL2-D15A has a power unit capacity of 15 with a special function rating A

Call now for best pricing
1-919-443-0207
Check Out Our Repair Page
Series:BL2-D or BLII-D
Power unit capacity:15
Special Function:A
BL2-D15A has a power unit capacity of 15 with a special function rating A. The type A unit is a brushless motor driving unit which controls current to it’s brushless motor according to the commands being sent from the servo processor. BL2-D15A features a supplying command current, no added need for exteranl circuits, indicating alarms and LEDs, and a dynamic brake funcation.

 What is a BDII-D?

The BLII-D type A unit, is a brushless motor driving unit. The BLII-D type A controls current to the brushless motor according to the current commands sent from the servo processor board (SVP IID).

Features:

Supplying commanded current to the motor in PWM method by IGBT.

Eliminating the necessity for adding external circuits thanks to the built-in circuit for discharging regenerative energy.

Indicating alarm with LEDs while transferring alarm data to SVP IID by two-way communication function.

Braking the motor by DB (dynamic brake) function.

 

Protecting the motor from overcurrent, overvoltage and overload.  Enabling compact design by addition of 2-axis unit to BL II-D series. Reducing wiring part by adoption of highly reliable large-current PC board.

Distribution Cache Shipping Info and Options

Shipping Carriers: Here at Distribution Cache we ship using UPS, FedEx, DHL, or TNT. In most cases we get very competitive rates based on our volume and will be happy quote shipping cost to your location upon request. We also know that many customers would prefer to ship collect on their own account numbers and welcome this option.

Shipping Blind: We recognize that many of our customers intend to re-sell the product to their end user. We respect our customer’s relationships with their clients and offer blind shipping as an option to ensure that the package arrives in the most clandestine way possible.

Shipping Process: We take pride in the way we package your order and spare no cost in making sure that it arrives safely at your facility. In the case of new parts, we are always sure to package the factory box inside another larger box for safe transit. For reconditioned parts we often use Distribution Cache customized packaging that is specially made to protect the products from the bumps and falls present during shipment.

 

Shipping Options:

Next Day Air Early AM - This service is the fastest overnight delivery option available. For most locations the package will be guaranteed by 8:30AM.

Next Day Air – This service guarantees delivery by 10:30AM and is the most frequently used option for overnight shipments.

Next Day Air Saver – This cost saving overnight alternative guarantees delivery by 3PM the next day.

2nd Day Air – For domestic shipments that would take 3-5 days if shipped via Ground, sometimes having the order in 2 days is a great way to go

Ground – Ground is the most inexpensive shipping option provided. Please ask if we are doing a “free domestic ground” shipping promotion on your order. We often provide free ground shipping on larger orders.

 

Emergency Courier – At times we can help work with a courier service to get the part to your facility during downtimes scenarios. We prefer that the customer sets up the courier but we can be there to make sure the product is handed off to the driver. Please give us a call to see if this is an option on your order.

Please Note: Products listed as “ships today” can ship same-day if an order is placed before 4PM. For larger drives and motors we ask that notification for same-day shipments be provided by 2PM at the latest. For any products listed as “ships in 3-5 days”, please give us a call to see if this can be expedited.

Unit Configuration

Order No. Name
A006-0600 SVC II BOARD 1-axis
A006-0601 SVC II BOARD 2-axis
.A.006-0610 BLII -D15A P.U
.11.006;0611 BLII-D30A P.U
Jl.006-0612 BLII -D50A P.U
Jl.006-0613 BLII-D75A P.U
A006-0614 BLII -D100A P.U
A006-0615 BLII -D150A P.U
11006-0620 BLII -D1515A P.U
11006-0621 BLII-D3015A P.U
J006-0622 BLII -D5015A P.U
J006-0623 BLII-D7515A P.U
J006-0624  
   
   
J006-0625 BLII-D3030A P.U
Jl.006-0626 BLII-D5030A P.U
Jl.006-0627 BLII-D7530A P.U
A006-0628  
   
   
A006-0629 BLII-D5050A P.U
A006-0630 BLII-D7550A P.U
A006-0631  
   
   
A006-0632 BLII-D7575A P.U
A006-0644 ("1) BLII-D100AS P.U
A006-0645 ,1) BLII-D150AS P.U

 

Applicable Motor List

Unit Capacity Motor Output (kW)   Motor Type
15 Up to 0.8   BL-MH1OE-20, BL-MS1OE-30, BL-MH20E-20
30 0.8 to 1.5   BL-MH51E-20, BL-MS50E-20, BL-MH101E-12
50 1.5 to 2.5   BL-MH101E-20, BL-MS50E-30, BL-MH201E-12, BL-MS75E-20
BL-MS75E-30      
75 2.5 to 4.0   BL-MH201E-20, BL-MH101E-30, BL-MS125E-20, BL-MH301 E-12
       
BL-MS125E-30      
100 4.0 to 6.0   BL-MH401E-12, (BL-MH301E-20), (BL-MH201E-30)
150 4.0 to 8.0   BL-MH301E-20, BL-MH201E-30, BL-MS125E-60, BL-MH?OOE-10, BL-MH101E-60, BL-MS140E-30

 

Protective and Abnormality Detecting

  Function Purpose/Content
1 Protection from ground fault The circuit protector shuts off the power the moment ground fault occurs inside the servo amplifier or the motor.
2 Protection of control power source from overcurrent The 3.2 A fuse is blown by the overcurrent from the power circuit caused by control circuit failure. Power is thus shut off immediately.
3 Motor transient overcurrent (OCM) When a large current exceeding 150 % of the limit value flows into the motor, an alarm occurs to prevent breakage of main circuit elements and motor demagnetization.
4 Short-drcuit in DC power source (OCS) When the inverter DC power is shorted because of the trouble in main circuit elements or control circuit, or when an overcurrent flows because of ground fault inside the motor, an alarm occurs to prevent secondary breakage of the main circuit elements.
5 Abnormally high voltage (OV) If the inverter DC power voltage increases to an abnormally high level, an alarm occurs to prevent breakage of the main circuit elements.
6 Abnormally low voltage (UV) If the inverter DC power voltage decreases to an abnormally low level, an alarm occurs to prevent unstable operation of the motor.
7 Reger,erative energy discharge resistance overheat (ROH) If the regenerative energy discharge resistances pass the current continuously or is overheated by excessive regenerative energy, an alarm occurs to prevent burning of the resistances.
8 Power board overheat (BOH) If the power board is overheated by the trouble in main circuit elements or control circuit, an alarm occurs to prevent burning of the board.
9 Abnormal power in control circuit (LOSS) If the control circuit voltage exceeds the safety operation range because of circuit failure, an alarm occurs to prevent malfunction of the circuit.