779507-01

National Instruments

779507-01

National Instruments

Description

Part number 779507-01, the National Instruments ExpressCard-8360 MXI-Express Interface is a single channel MXI Express module with a high-speed connector cable and kit for seamless connection to other devices. Fully compatible with PXI hardware, this ExpressCard is designed for high-performance control of PXI systems via servers, workstations, and laptops.

779507-01 NI ExpressCard-8360, ExpressCard MXI Interface National Instruments ExpressCard-8360 MXI-Express Interface is a single channel MXI Express module. The ExpressCard-8360 kit includes a high-speed connector cable, cable driver, and an express card module connector. This ExpressCard 8360, manufactured by National Instruments and identified by part number 779507-01, is designed to connect with other devices featuring the same built-in high-speed cable connector, providing all necessary signals for the connection, including a system clock and reset signal. Fully compatible with PXI hardware specifications, the National Instruments ExpressCard-8360 has a maximum cable length of 7 meters. Operating at +3.3 V Aux, the ExpressCard 8360 requires a maximum 20 mA current, or a maximum of 30 mA. Ideal for indoor use only, the ExpressCard-8360 can withstand a non-operating thermal shock of -20° to 65° C, 5 times up to 5 ms. With a high bandwidth serial connection, transparent to drivers, software, and applications, the ExpressCard-8360 allows for control of PXI systems via servers, workstations, laptops, and high-performance desktop systems. Installation requirements include one ExpressCard/34 or ExpressCard/54 slot, with full functionality requiring the installation of the PXI Platform service software. The ExpressCard 8360 is also compatible with MXI-Express BIOS, toggled via software rather than physical dip switches.

Made By National Instruments
Part Number 779507-01 NI ExpressCard-8360
Interface Type ExpressCard MXI Interface
Compatibility PXI hardware
Maximum Cable Length 7 m
Operating Current and Voltage +3.3 V Aux at 20 mA (max.), 30 mA (max.)

Distribution Cache Shipping Info and Options

Shipping Carriers: Here at Distribution Cache we ship using UPS, FedEx, DHL, or TNT. In most cases we get very competitive rates based on our volume and will be happy quote shipping cost to your location upon request. We also know that many customers would prefer to ship collect on their own account numbers and welcome this option.

Shipping Blind: We recognize that many of our customers intend to re-sell the product to their end user. We respect our customer’s relationships with their clients and offer blind shipping as an option to ensure that the package arrives in the most clandestine way possible.

Shipping Process: We take pride in the way we package your order and spare no cost in making sure that it arrives safely at your facility. In the case of new parts, we are always sure to package the factory box inside another larger box for safe transit. For reconditioned parts we often use Distribution Cache customized packaging that is specially made to protect the products from the bumps and falls present during shipment.

 

Shipping Options:

Next Day Air Early AM - This service is the fastest overnight delivery option available. For most locations the package will be guaranteed by 8:30AM.

Next Day Air – This service guarantees delivery by 10:30AM and is the most frequently used option for overnight shipments.

Next Day Air Saver – This cost saving overnight alternative guarantees delivery by 3PM the next day.

2nd Day Air – For domestic shipments that would take 3-5 days if shipped via Ground, sometimes having the order in 2 days is a great way to go

Ground – Ground is the most inexpensive shipping option provided. Please ask if we are doing a “free domestic ground” shipping promotion on your order. We often provide free ground shipping on larger orders.

 

Emergency Courier – At times we can help work with a courier service to get the part to your facility during downtimes scenarios. We prefer that the customer sets up the courier but we can be there to make sure the product is handed off to the driver. Please give us a call to see if this is an option on your order.

Please Note: Products listed as “ships today” can ship same-day if an order is placed before 4PM. For larger drives and motors we ask that notification for same-day shipments be provided by 2PM at the latest. For any products listed as “ships in 3-5 days”, please give us a call to see if this can be expedited.

Question:

What is the maximum cable length supported by the National Instruments ExpressCard-8360 model 779507-01?

Answer:

The maximum cable length supported by the National Instruments ExpressCard-8360 model 779507-01 is 7 meters.

Question:

Which operating voltage is required for the NI ExpressCard-8360, and what is the maximum current it draws?

Answer:

The NI ExpressCard-8360 operates at +3.3 V Aux and requires a maximum current of either 20 mA or 30 mA.

Question:

What are the indoor non-operating thermal shock specifications for the ExpressCard-8360?

Answer:

For indoor non-operating conditions, the ExpressCard-8360 can withstand a thermal shock of -20 to 65 C, repeated 5 times for up to 5 ms.

Question:

Can the ExpressCard-8360 connect to PXI systems for control purposes, and if so, what types of systems is it compatible with?

Answer:

Yes, the ExpressCard-8360 can connect to PXI systems for control purposes and is compatible with servers, workstations, laptops, and high-performance desktop systems.

Question:

What installation requirements are necessary for the ExpressCard-8360, and what software is required for full functionality?

Answer:

The installation requirements for the ExpressCard-8360 include one ExpressCard/34 or ExpressCard/54 slot. Full functionality requires installation of the PXI Platform service software.