184146A-01
National Instruments
184146A-01
National Instruments
Description
The 184146A-01 National Instruments VXI-1500 is a VXI Mainframe designed for multiple applications, featuring 13 slots and a high-output power supply for efficient operation. Built in line with the VXIbus Specification Revision 1.4, this mainframe has a low mean time to repair (MTTR) and can accommodate various module sizes without backplane jumpers.
184146A-01 National Instruments VXI-1500 is a VXI Mainframe designed for maximum use in multiple applications. This mainframe features a backplane with 13 slots and a high-output power supply for efficient operation. The VXI-1500 is in line with the VXIbus Specification Revision 1.4 and is built with a low mean time to repair (MTTR) for ease of maintenance. It is equipped with 13 C-sized VXIbus slots that can also accommodate A-sized and B-sized modules with the use of adapters, without the need for backplane jumpers. The VXI-1500 utilizes 1100 W of heat dissipation through filtered forced-air cooling, with a power input of 1100 W (115 VAC) or 1420 W (230 VAC). This mainframe is manufactured with a universal AC input for auto-voltage and auto-operation.
| Made By | National Instruments |
|---|---|
| Part Number | 184146A-01 |
| Manufacturer | National Instruments |
| Slots Capacity | 13 C-sized VXIbus slots (compatible with A-sized and B-sized modules with adapters) |
| Power Supply Options | 1100 W (115 VAC input) or 1420 W (230 VAC input) |
| Cooling Mechanism | Filtered forced-air cooling with 1100 W of heat dissipation |
Distribution Cache Shipping Info and Options
Shipping Carriers: Here at Distribution Cache we ship using UPS, FedEx, DHL, or TNT. In most cases we get very competitive rates based on our volume and will be happy quote shipping cost to your location upon request. We also know that many customers would prefer to ship collect on their own account numbers and welcome this option.
Shipping Blind: We recognize that many of our customers intend to re-sell the product to their end user. We respect our customer’s relationships with their clients and offer blind shipping as an option to ensure that the package arrives in the most clandestine way possible.
Shipping Process: We take pride in the way we package your order and spare no cost in making sure that it arrives safely at your facility. In the case of new parts, we are always sure to package the factory box inside another larger box for safe transit. For reconditioned parts we often use Distribution Cache customized packaging that is specially made to protect the products from the bumps and falls present during shipment.
Shipping Options:
Next Day Air Early AM - This service is the fastest overnight delivery option available. For most locations the package will be guaranteed by 8:30AM.
Next Day Air – This service guarantees delivery by 10:30AM and is the most frequently used option for overnight shipments.
Next Day Air Saver – This cost saving overnight alternative guarantees delivery by 3PM the next day.
2nd Day Air – For domestic shipments that would take 3-5 days if shipped via Ground, sometimes having the order in 2 days is a great way to go
Ground – Ground is the most inexpensive shipping option provided. Please ask if we are doing a “free domestic ground” shipping promotion on your order. We often provide free ground shipping on larger orders.
Emergency Courier – At times we can help work with a courier service to get the part to your facility during downtimes scenarios. We prefer that the customer sets up the courier but we can be there to make sure the product is handed off to the driver. Please give us a call to see if this is an option on your order.
Please Note: Products listed as “ships today” can ship same-day if an order is placed before 4PM. For larger drives and motors we ask that notification for same-day shipments be provided by 2PM at the latest. For any products listed as “ships in 3-5 days”, please give us a call to see if this can be expedited.
Question:
What is the National Instruments model number for the VXI Mainframe described?
Answer:
The National Instruments model number for the described VXI Mainframe is 184146A-01.
Question:
How many slots does the 184146A-01 VXI Mainframe backplane feature, and what sizes are supported?
Answer:
The backplane of the 184146A-01 VXI Mainframe features 13 slots and supports C-sized VXIbus slots, with the ability to also accommodate A-sized and B-sized modules using adapters.
Question:
What is the power dissipation capacity of the VXI-1500 and what are the power input specifications?
Answer:
The VXI-1500 has a heat dissipation capacity of 1100 W through filtered forced-air cooling, and its power input specifications are 1100 W (115 VAC) or 1420 W (230 VAC).
Question:
What VXIbus Specification does the VXI-1500 comply with?
Answer:
The VXI-1500 complies with the VXIbus Specification Revision 1.4.
Question:
What features of the 184146A-01 VXI Mainframe contribute to its low mean time to repair (MTTR)?
Answer:
The low mean time to repair (MTTR) of the 184146A-01 VXI Mainframe is attributed to its design, which does not require backplane jumpers for A-sized and B-sized modules, and its compatibility with multiple applications that ease maintenance procedures.