154487A-02L

National Instruments

154487A-02L

National Instruments

154487A-02L Image 1

Description

Part number 154487A-02L is the National Instruments PXIe-5170 High-Density Oscilloscope, featuring eight channels sampled simultaneously and programmable FPGA for signal processing. This versatile instrument offers 14-bit resolution, 250 Msample/sec sample rate, and programmable digital IO-lines for trigger signals or communication with other devices.

Part number 154487A-02L refers to the National Instruments PXIe-5170 High-Density Oscilloscope. This versatile instrument features eight channels sampled simultaneously, with flexible configuration options for coupling and voltage range. The PXIe-5170 includes a programmable FPGA for signal processing, protocol decoding, and trigger schemes without dead time. With four or eight calibrated analog input channels, 14-bit resolution, and a sample rate of 250 Msample/sec, this oscilloscope can handle a wide range of applications. Additionally, it offers programmable digital IO-lines for trigger signals or communication with other devices using serial protocols. The high-throughput PXI-Express interface allows for streaming at 3.2 GB/sec, and the user can program the FPGA with Labview for custom signal processing capabilities. It is essential to adhere to the guidelines in the Maintain Forced-Air Cooling Manual for proper installation and cooling of the PXIe-5170.

Made By National Instruments
Part number 154487A-02L
Number of channels Eight channels
Resolution and sample rate 14-bit resolution, 250 Msample/sec
Analog input voltage range 200 mVpp to 5 Vpp
Digital IO-lines Eight programmable lines

Distribution Cache Shipping Info and Options

Shipping Carriers: Here at Distribution Cache we ship using UPS, FedEx, DHL, or TNT. In most cases we get very competitive rates based on our volume and will be happy quote shipping cost to your location upon request. We also know that many customers would prefer to ship collect on their own account numbers and welcome this option.

Shipping Blind: We recognize that many of our customers intend to re-sell the product to their end user. We respect our customer’s relationships with their clients and offer blind shipping as an option to ensure that the package arrives in the most clandestine way possible.

Shipping Process: We take pride in the way we package your order and spare no cost in making sure that it arrives safely at your facility. In the case of new parts, we are always sure to package the factory box inside another larger box for safe transit. For reconditioned parts we often use Distribution Cache customized packaging that is specially made to protect the products from the bumps and falls present during shipment.

 

Shipping Options:

Next Day Air Early AM - This service is the fastest overnight delivery option available. For most locations the package will be guaranteed by 8:30AM.

Next Day Air – This service guarantees delivery by 10:30AM and is the most frequently used option for overnight shipments.

Next Day Air Saver – This cost saving overnight alternative guarantees delivery by 3PM the next day.

2nd Day Air – For domestic shipments that would take 3-5 days if shipped via Ground, sometimes having the order in 2 days is a great way to go

Ground – Ground is the most inexpensive shipping option provided. Please ask if we are doing a “free domestic ground” shipping promotion on your order. We often provide free ground shipping on larger orders.

 

Emergency Courier – At times we can help work with a courier service to get the part to your facility during downtimes scenarios. We prefer that the customer sets up the courier but we can be there to make sure the product is handed off to the driver. Please give us a call to see if this is an option on your order.

Please Note: Products listed as “ships today” can ship same-day if an order is placed before 4PM. For larger drives and motors we ask that notification for same-day shipments be provided by 2PM at the latest. For any products listed as “ships in 3-5 days”, please give us a call to see if this can be expedited.

Question:

What is the part number 154487A-02L referred to?

Answer:

The part number 154487A-02L refers to the National Instruments PXIe-5170 High-Density Oscilloscope.

Question:

How many channels does the PXIe-5170 Oscilloscope have, and are they sampled simultaneously?

Answer:

The PXIe-5170 Oscilloscope features eight channels that are sampled simultaneously.

Question:

What is the resolution and sample rate of the PXIe-5170 Oscilloscope?

Answer:

The PXIe-5170 Oscilloscope has a 14-bit resolution and a sample rate of 250 Msample/sec.

Question:

Can the PXIe-5170 Oscilloscope's FPGA be programmed, and if so, with which tool?

Answer:

Yes, the FPGA on the PXIe-5170 Oscilloscope can be programmed with Labview for custom signal processing capabilities.

Question:

What is the importance of adhering to the guidelines in the Maintain Forced-Air Cooling Manual for the PXIe-5170?

Answer:

It is important to adhere to the guidelines in the Maintain Forced-Air Cooling Manual for proper installation and cooling of the PXIe-5170, to ensure the device functions correctly and safely.