150227E-02L
National Instruments
150227E-02L
National Instruments

Description
The National Instruments cDAQ-9181 CompactDAQ Chassis, part 150227E-02L, is a 1-slot Ethernet chassis designed for C Series simple input modules, ideal for measuring gradual signal changes like temperature. When using these modules with the cDAQ-9181 chassis, it is important to note that the maximum sample rate may exceed the module’s maximum rate, but the chassis also offers Reference Trigger options for stopping measurement acquisition.
The part 150227E-02L is the National Instruments cDAQ-9181 CompactDAQ Chassis, a 1-slot Ethernet chassis designed for use with C Series simple input modules. These modules are ideal for measuring signals that change gradually, such as temperature. It is important to note that when using these modules with the cDAQ-9181 chassis, the maximum sample rate may exceed the module's maximum rate. The chassis also allows for the use of Reference Trigger to stop measurement acquisition, with options for pre-trigger and post-trigger tests. By inserting a simple input C Series module into the chassis, users can customize channel configurations and other specifications based on the module being used. It is important to note that channels must be assigned to either a hardware timed task or a software timed task, but not a mix of both on the same module.
Made By | National Instruments |
---|---|
Part Number | 150227E-02L |
Chassis Type | cDAQ-9181 CompactDAQ Chassis (1 Slot, Ethernet) |
Maximum Sample Rate | Faster than maximum rate for the module |
Compatible Modules | C Series simple input modules |
Reference Trigger | Utilize for pre-trigger and post-trigger sample acquisition |
Distribution Cache Shipping Info and Options
Shipping Carriers: Here at Distribution Cache we ship using UPS, FedEx, DHL, or TNT. In most cases we get very competitive rates based on our volume and will be happy quote shipping cost to your location upon request. We also know that many customers would prefer to ship collect on their own account numbers and welcome this option.
Shipping Blind: We recognize that many of our customers intend to re-sell the product to their end user. We respect our customer’s relationships with their clients and offer blind shipping as an option to ensure that the package arrives in the most clandestine way possible.
Shipping Process: We take pride in the way we package your order and spare no cost in making sure that it arrives safely at your facility. In the case of new parts, we are always sure to package the factory box inside another larger box for safe transit. For reconditioned parts we often use Distribution Cache customized packaging that is specially made to protect the products from the bumps and falls present during shipment.
Shipping Options:
Next Day Air Early AM - This service is the fastest overnight delivery option available. For most locations the package will be guaranteed by 8:30AM.
Next Day Air – This service guarantees delivery by 10:30AM and is the most frequently used option for overnight shipments.
Next Day Air Saver – This cost saving overnight alternative guarantees delivery by 3PM the next day.
2nd Day Air – For domestic shipments that would take 3-5 days if shipped via Ground, sometimes having the order in 2 days is a great way to go
Ground – Ground is the most inexpensive shipping option provided. Please ask if we are doing a “free domestic ground” shipping promotion on your order. We often provide free ground shipping on larger orders.
Emergency Courier – At times we can help work with a courier service to get the part to your facility during downtimes scenarios. We prefer that the customer sets up the courier but we can be there to make sure the product is handed off to the driver. Please give us a call to see if this is an option on your order.
Please Note: Products listed as “ships today” can ship same-day if an order is placed before 4PM. For larger drives and motors we ask that notification for same-day shipments be provided by 2PM at the latest. For any products listed as “ships in 3-5 days”, please give us a call to see if this can be expedited.
Question:
What is the National Instruments part number 150227E-02L?
Answer:
The part number 150227E-02L is the National Instruments cDAQ-9181 CompactDAQ Chassis, which is a 1-slot Ethernet chassis designed for use with C Series simple input modules.
Question:
What type of input modules is the cDAQ-9181 chassis intended for?
Answer:
The cDAQ-9181 chassis is designed for use with C Series simple input modules, which are ideal for measuring signals that change gradually, such as temperature.
Question:
Is there any limitation to be aware of when using modules with the cDAQ-9181 chassis?
Answer:
Yes, it is important to note that when using modules with the cDAQ-9181 chassis, the maximum sample rate may exceed the module's maximum rate.
Question:
What feature does the cDAQ-9181 chassis provide for measurement acquisition?
Answer:
The cDAQ-9181 chassis allows for the use of Reference Trigger to stop measurement acquisition, with options for pre-trigger and post-trigger tests.
Question:
When inserting a C Series module into the cDAQ-9181 chassis, what must users remember about channel assignments?
Answer:
Users must remember that channels must be assigned to either a hardware timed task or a software timed task, but not a mix of both on the same module.