cFP-AI-110

National Instruments

cFP-AI-110

National Instruments

Description

The cFP-AI-110 is a versatile analog input module by National Instruments, offering a wide range of input options for voltage and current measurements. With its impressive update rate and compatibility with industrial applications, it provides reliable and accurate measurements for optimal performance in various setups.

The cFP-AI-110 is a model of the analog input module manufactured by National Instruments. It is designed to provide accurate and reliable measurements of voltage and current with its 8-channel, 16-bit capability. The part number of this module is 777318-110. With a wide range of input options, the cFP-AI-110 offers great flexibility. For voltage measurements, it supports input ranges of 0-1 V, 0-5 V, 0-10 V, 60 mV, 300 mV, 1 V, 5 V, and 10 V. On the other hand, for current measurements, the input ranges include 0-20 mA, 4-20 mA, and 20 mA. This wide selection ensures compatibility with various devices and applications. One of the key features of the cFP-AI-110 is its impressive update rate, which ranges from 5 Hz to 0.66 Hz on all channels. This high update rate ensures that real-time data acquisition can be achieved accurately and promptly. Whether it's monitoring fast-changing signals or slow-varying measurements, this module can handle it effectively. The cFP-AI-110 is suitable for a wide range of industrial applications that require precise and efficient analog input measurements. Its robust design and compatibility with CompactFieldPoint systems make it ideal for integration into existing setups. Whether it's monitoring voltage levels, current fluctuations, or any other analog signals, this module provides reliable and accurate measurements to ensure optimal performance.

Made By National Instruments
Model Number cFP-AI-110
Part Number 777318-110
Type 8-Channel, 16-Bit Voltage and Current, Analog Input Module
Update Rate 5 Hz to 0.66 Hz on all channels
Input Ranges Voltage: 0-1 V, 0-5 V, 0-10 V, 60 mV, 300 mV, 1 V, 5 V, 10 V; Current: 0-20 mA, 4-20 mA, 20 mA

Distribution Cache Shipping Info and Options

Shipping Carriers: Here at Distribution Cache we ship using UPS, FedEx, DHL, or TNT. In most cases we get very competitive rates based on our volume and will be happy quote shipping cost to your location upon request. We also know that many customers would prefer to ship collect on their own account numbers and welcome this option.

Shipping Blind: We recognize that many of our customers intend to re-sell the product to their end user. We respect our customer’s relationships with their clients and offer blind shipping as an option to ensure that the package arrives in the most clandestine way possible.

Shipping Process: We take pride in the way we package your order and spare no cost in making sure that it arrives safely at your facility. In the case of new parts, we are always sure to package the factory box inside another larger box for safe transit. For reconditioned parts we often use Distribution Cache customized packaging that is specially made to protect the products from the bumps and falls present during shipment.

 

Shipping Options:

Next Day Air Early AM - This service is the fastest overnight delivery option available. For most locations the package will be guaranteed by 8:30AM.

Next Day Air – This service guarantees delivery by 10:30AM and is the most frequently used option for overnight shipments.

Next Day Air Saver – This cost saving overnight alternative guarantees delivery by 3PM the next day.

2nd Day Air – For domestic shipments that would take 3-5 days if shipped via Ground, sometimes having the order in 2 days is a great way to go

Ground – Ground is the most inexpensive shipping option provided. Please ask if we are doing a “free domestic ground” shipping promotion on your order. We often provide free ground shipping on larger orders.

 

Emergency Courier – At times we can help work with a courier service to get the part to your facility during downtimes scenarios. We prefer that the customer sets up the courier but we can be there to make sure the product is handed off to the driver. Please give us a call to see if this is an option on your order.

Please Note: Products listed as “ships today” can ship same-day if an order is placed before 4PM. For larger drives and motors we ask that notification for same-day shipments be provided by 2PM at the latest. For any products listed as “ships in 3-5 days”, please give us a call to see if this can be expedited.

Question:

What is the function of the cFP-AI-110?

Answer:

The cFP-AI-110 is designed to provide accurate and reliable measurements of voltage and current with its 8-channel, 16-bit capability.

Question:

What input ranges does the cFP-AI-110 support for voltage measurements?

Answer:

For voltage measurements, the cFP-AI-110 supports input ranges of 0-1 V, 0-5 V, 0-10 V, 60 mV, 300 mV, 1 V, 5 V, and 10 V.

Question:

What are the current measurement input ranges of the cFP-AI-110?

Answer:

The current measurement input ranges for the cFP-AI-110 include 0-20 mA, 4-20 mA, and 20 mA.

Question:

How fast is the update rate of the cFP-AI-110?

Answer:

The update rate of the cFP-AI-110 ranges from 5 Hz to 0.66 Hz on all channels.

Question:

What type of applications is the cFP-AI-110 ideal for?

Answer:

The cFP-AI-110 is suitable for a wide range of industrial applications that require precise and efficient analog input measurements, such as monitoring voltage levels, current fluctuations, or other analog signals.