142889C-01L
National Instruments
142889C-01L
National Instruments
Description
The 142889C-01L USB-8506-LIN-1 Port National Instruments USB-8506 LIN Interface Device is a powerful tool for creating applications with the NI-XNET driver, allowing users to check for system issues autonomously using nxReadState. By deliberately introducing noise into the CAN links, users can test how the Electronic Control Unit (ECU) behaves under various conditions, making this interface essential for efficient and error-free testing and monitoring of LIN systems.
The 142889C-01L USB-8506-LIN-1 Port National Instruments USB-8506 LIN Interface Device is a powerful tool for creating applications with the NI-XNET driver. This Local Interconnect Network (LIN) Interface Device allows the user to check for system issues autonomously using nxReadState. By deliberately introducing noise into the CAN links, the user can test how the Electronic Control Unit (ECU) behaves under various conditions. The device's starting state is off, as it is not communicating with other nodes (ECUs). When the start trigger is initiated, the interface transitions from Idle to Active state. Stopping the device returns it to the Idle state. The user can also synchronize the start trigger of another XNET or DAQ card to ensure simultaneous sampling on both devices. This versatile interface, part number 142889C-01L, is essential for efficient and error-free testing and monitoring of LIN systems.
| Made By | National Instruments |
|---|---|
| Part Number | 142889C-01L |
| Compatible Interface | USB-8506 LIN |
| Driver Compatibility | NI-XNET |
| Operational States | Idle, Active, and Inactive states |
| State Checking Function | nxReadState |
Distribution Cache Shipping Info and Options
Shipping Carriers: Here at Distribution Cache we ship using UPS, FedEx, DHL, or TNT. In most cases we get very competitive rates based on our volume and will be happy quote shipping cost to your location upon request. We also know that many customers would prefer to ship collect on their own account numbers and welcome this option.
Shipping Blind: We recognize that many of our customers intend to re-sell the product to their end user. We respect our customer’s relationships with their clients and offer blind shipping as an option to ensure that the package arrives in the most clandestine way possible.
Shipping Process: We take pride in the way we package your order and spare no cost in making sure that it arrives safely at your facility. In the case of new parts, we are always sure to package the factory box inside another larger box for safe transit. For reconditioned parts we often use Distribution Cache customized packaging that is specially made to protect the products from the bumps and falls present during shipment.
Shipping Options:
Next Day Air Early AM - This service is the fastest overnight delivery option available. For most locations the package will be guaranteed by 8:30AM.
Next Day Air – This service guarantees delivery by 10:30AM and is the most frequently used option for overnight shipments.
Next Day Air Saver – This cost saving overnight alternative guarantees delivery by 3PM the next day.
2nd Day Air – For domestic shipments that would take 3-5 days if shipped via Ground, sometimes having the order in 2 days is a great way to go
Ground – Ground is the most inexpensive shipping option provided. Please ask if we are doing a “free domestic ground” shipping promotion on your order. We often provide free ground shipping on larger orders.
Emergency Courier – At times we can help work with a courier service to get the part to your facility during downtimes scenarios. We prefer that the customer sets up the courier but we can be there to make sure the product is handed off to the driver. Please give us a call to see if this is an option on your order.
Please Note: Products listed as “ships today” can ship same-day if an order is placed before 4PM. For larger drives and motors we ask that notification for same-day shipments be provided by 2PM at the latest. For any products listed as “ships in 3-5 days”, please give us a call to see if this can be expedited.
Question:
What is the part number for the National Instruments USB LIN Interface Device?
Answer:
The part number for the National Instruments USB LIN Interface Device is 142889C-01L.
Question:
Which driver is used with the 142889C-01L LIN Interface Device?
Answer:
The NI-XNET driver is used with the 142889C-01L LIN Interface Device.
Question:
What functionality does the 142889C-01L device support to check system issues?
Answer:
The 142889C-01L device supports the use of nxReadState to check for system issues autonomously.
Question:
How does the 142889C-01L assist in testing ECU behavior under various conditions?
Answer:
The 142889C-01L can introduce noise into the CAN links to test how the Electronic Control Unit (ECU) behaves under various conditions.
Question:
What states does the 142889C-01L transition between and how is it synchronized with other devices?
Answer:
The 142889C-01L transitions between Idle and Active states when the start trigger is initiated. It can also be synchronized with the start trigger of another XNET or DAQ card for simultaneous sampling.