140185E-02L
National Instruments
140185E-02L
National Instruments

Description
The 140185E-02L, also known as the National Instruments PXIe-4162 PXI Source Measure Unit, is a high-density SMU unit with 12 channels featuring customizable transient response for stable and accurate measurements. Ideal for testing mixed signal integrated circuits in semiconductor production, it has a voltage range of -24 V to 24 V and a current range of -100 mA to 100 mA, requiring the NI-DCPower driver software for operation.
The 140185E-02L, also known as the National Instruments PXIe-4162 PXI Source Measure Unit, is a high-density SMU unit with 12 channels. It features 4 quadrant activity, a current resolution of 100 pA, and the ability to test up to 100 kS/s. With the SourceAdapt feature, users can customize transient response for greater stability and measurement accuracy. Perfect for testing mixed signal integrated circuits in semiconductor production, this device has a voltage range of -24 V to 24 V and a current range of -100 mA to 100 mA. To operate the PXIe-4162, the NI-DCPower driver software is required, which can be configured using LabVIEW or LabWindows/CVI. The device can be reset and recalibrated, with recommended calibration periods varying from annual to biennial. Apex Waves offers NIST accredited calibrations with a turnaround time of 1 to 2 weeks. Contact us for more information on calibrating the PXIe-4162!
Made By | National Instruments |
---|---|
Part Number | 140185E-02L (785680-01) |
Type of Device | PXI Source Measure Unit (SMU) |
Channel Count | 12 SMU Channels |
Voltage Range | -24 V to 24 V |
Current Range | -100 mA to 100 mA |
Distribution Cache Shipping Info and Options
Shipping Carriers: Here at Distribution Cache we ship using UPS, FedEx, DHL, or TNT. In most cases we get very competitive rates based on our volume and will be happy quote shipping cost to your location upon request. We also know that many customers would prefer to ship collect on their own account numbers and welcome this option.
Shipping Blind: We recognize that many of our customers intend to re-sell the product to their end user. We respect our customer’s relationships with their clients and offer blind shipping as an option to ensure that the package arrives in the most clandestine way possible.
Shipping Process: We take pride in the way we package your order and spare no cost in making sure that it arrives safely at your facility. In the case of new parts, we are always sure to package the factory box inside another larger box for safe transit. For reconditioned parts we often use Distribution Cache customized packaging that is specially made to protect the products from the bumps and falls present during shipment.
Shipping Options:
Next Day Air Early AM - This service is the fastest overnight delivery option available. For most locations the package will be guaranteed by 8:30AM.
Next Day Air – This service guarantees delivery by 10:30AM and is the most frequently used option for overnight shipments.
Next Day Air Saver – This cost saving overnight alternative guarantees delivery by 3PM the next day.
2nd Day Air – For domestic shipments that would take 3-5 days if shipped via Ground, sometimes having the order in 2 days is a great way to go
Ground – Ground is the most inexpensive shipping option provided. Please ask if we are doing a “free domestic ground” shipping promotion on your order. We often provide free ground shipping on larger orders.
Emergency Courier – At times we can help work with a courier service to get the part to your facility during downtimes scenarios. We prefer that the customer sets up the courier but we can be there to make sure the product is handed off to the driver. Please give us a call to see if this is an option on your order.
Please Note: Products listed as “ships today” can ship same-day if an order is placed before 4PM. For larger drives and motors we ask that notification for same-day shipments be provided by 2PM at the latest. For any products listed as “ships in 3-5 days”, please give us a call to see if this can be expedited.
Question:
What is the National Instruments 140185E-02L?
Answer:
The National Instruments 140185E-02L is a type of high-density Source Measure Unit (SMU) known as the PXIe-4162 PXI Source Measure Unit with 12 channels.
Question:
What are the key features of the PXIe-4162?
Answer:
The PXIe-4162 features 4 quadrant activity, a current resolution of 100 pA, the ability to test up to 100 kS/s, a SourceAdapt feature to customize transient response, a voltage range of -24 V to 24 V, and a current range of -100 mA to 100 mA.
Question:
What is the SourceAdapt feature on the PXIe-4162 used for?
Answer:
The SourceAdapt feature on the PXIe-4162 is used to customize transient response which enhances stability and measurement accuracy.
Question:
What is required to operate the PXIe-4162?
Answer:
To operate the PXIe-4162, the NI-DCPower driver software is required and can be configured using LabVIEW or LabWindows/CVI.
Question:
What is the recommended calibration period for the PXIe-4162, and who offers calibrations?
Answer:
The recommended calibration period for the PXIe-4162 varies from annual to biennial, and Apex Waves offers NIST accredited calibrations with a turnaround time of 1 to 2 weeks.