780159-01

National Instruments

780159-01

National Instruments

Description

National Instruments 9225 3-Ch +/-300V Analog Input Country of Origin Hungary

The 780159-01 NI 9225 C Series Voltage Input Module, also known as part number 780159-01, is designed for waveform estimations of high-voltage signals. This module is capable of measuring up to 300 Vrms, allowing for line-to-neutral and line-to-line measurements of 110 V power systems, as well as line-to-neutral measurements of 240 V power networks. With three channels, the NI 9225 is ideal for three-phase systems and is essential for monitoring power quality events such as sags, swells, transients, and harmonics. When paired with the NI 9239 (10 V) and a current transducer, the NI 9225 can be used to create a customizable power quality monitoring or power metering system. The NI 9225 offers high-precision measurements and features measurement-specific signal conditioning, channel-to-channel isolation, and support for a wide temperature range. This module has a compact design with a screw terminal front connector, making it easy to install and use. The NI-9225 C Series Voltage Input Module has three differential analog input channels, a maximum sample rate of 50 kS/s per channel, and a resolution of 24 bits. Its operating temperature range is -40 to 70 °C, and it has a power consumption of 495 mW in active mode. Calibration services are available for the NI-9225 to ensure accuracy and reliability. Contact Apex Waves for more information on calibration options and to learn more about the capabilities of the NI 9225.

Distribution Cache Shipping Info and Options

Shipping Carriers: Here at Distribution Cache we ship using UPS, FedEx, DHL, or TNT. In most cases we get very competitive rates based on our volume and will be happy quote shipping cost to your location upon request. We also know that many customers would prefer to ship collect on their own account numbers and welcome this option.

Shipping Blind: We recognize that many of our customers intend to re-sell the product to their end user. We respect our customer’s relationships with their clients and offer blind shipping as an option to ensure that the package arrives in the most clandestine way possible.

Shipping Process: We take pride in the way we package your order and spare no cost in making sure that it arrives safely at your facility. In the case of new parts, we are always sure to package the factory box inside another larger box for safe transit. For reconditioned parts we often use Distribution Cache customized packaging that is specially made to protect the products from the bumps and falls present during shipment.

 

Shipping Options:

Next Day Air Early AM - This service is the fastest overnight delivery option available. For most locations the package will be guaranteed by 8:30AM.

Next Day Air – This service guarantees delivery by 10:30AM and is the most frequently used option for overnight shipments.

Next Day Air Saver – This cost saving overnight alternative guarantees delivery by 3PM the next day.

2nd Day Air – For domestic shipments that would take 3-5 days if shipped via Ground, sometimes having the order in 2 days is a great way to go

Ground – Ground is the most inexpensive shipping option provided. Please ask if we are doing a “free domestic ground” shipping promotion on your order. We often provide free ground shipping on larger orders.

 

Emergency Courier – At times we can help work with a courier service to get the part to your facility during downtimes scenarios. We prefer that the customer sets up the courier but we can be there to make sure the product is handed off to the driver. Please give us a call to see if this is an option on your order.

Please Note: Products listed as “ships today” can ship same-day if an order is placed before 4PM. For larger drives and motors we ask that notification for same-day shipments be provided by 2PM at the latest. For any products listed as “ships in 3-5 days”, please give us a call to see if this can be expedited.

Question:

What is the primary purpose of the NI 9225 C Series Voltage Input Module?

Answer:

The primary purpose of the NI 9225 C Series Voltage Input Module is for waveform estimations of high-voltage signals, making it ideal for monitoring power quality events such as sags, swells, transients, and harmonics.

Question:

What is the maximum voltage that the NI 9225 can measure?

Answer:

The NI 9225 can measure up to 300 Vrms, suitable for both line-to-neutral and line-to-line measurements in various power systems.

Question:

How many channels does the NI 9225 module have, and why is this beneficial?

Answer:

The NI 9225 module has three channels, which is beneficial for monitoring three-phase systems that are commonly used in power distribution networks.

Question:

Describe the key features of the NI 9225 module's design and functionality.

Answer:

The NI 9225 offers high-precision measurements with features such as measurement-specific signal conditioning, channel-to-channel isolation, support for a wide temperature range, and a compact design with a screw terminal front connector for easy installation and use.

Question:

What are the technical specifications of the NI 9225 module regarding sampling rate, resolution, and power consumption?

Answer:

The NI 9225 module has a maximum sample rate of 50 kS/s per channel, a resolution of 24 bits, and a power consumption of 495 mW in active mode.