779615-01

National Instruments

779615-01

National Instruments

Description

779615-01 PCI-6230, 60 V Isolated (Analog Voltage: 8 SE Ch, 4 AO, Digital 5V TTL: 6 Inputs, 4 Outputs) National Instruments PCI-6230 Multifunction DAQ is a Bank Isolated, Multifunctional Data Acquisition Board from the M Series. This device offers an optimum combination of performance and safety benefits of isolation with high-performance amplification, timing, and calibration technologies required for accurate precision control and measurements.

779615-01 PCI-6230, 60 V Isolated (Analog Voltage: 8 SE Ch, 4 AO, Digital 5V TTL: 6 Inputs, 4 Outputs) National Instruments PCI-6230 Multifunction DAQ is a Bank Isolated, Multifunctional Data Acquisition Board from the M Series. This device offers an optimum combination of performance and safety benefits of isolation with high-performance amplification, timing, and calibration technologies required for accurate precision control and measurements. The bank isolation capability incorporated in the NI PCI-6230 brings noise rejection, safety from transients, reduced ground loops, as well as common-mode voltage rejection. This model is designed with four analog output channels backed by 16-bit Digital-to-Analog converters. The maximum achievable update rate per analog output channel is 500 kS/s. The user can achieve 450, 425, and 400 KS/s per channel update rate while operating with two, three, or four channels respectively. The NI PCI-6230 supports DC output coupling and has an output range of ±10 V. The PCI-6230 is run using the NIDAQmx driver software which can be programmed with software packages or application development environments (ADEs) such as LabVIEW or LabWindows/CVI. The NI device weighs 0.24 lb, and measures 3.8 x 6.1 in. in physical dimensions. It has a recommended operating temperature range of 0 to 55 °C. PCI-6230 Legacy Status has been announced by National Instruments, but will still be available for purchase and repairs by Apex Waves. The PCI-6230 is available to be calibrated. While the recommended calibration period for individual parts varies, most parts should be calibrated either annually or every two years to ensure accuracy. If you need the PCI-6230 calibrated, Apex Waves provides options. We offer high-quality NIST accredited calibrations through a 3rd party, with an average turnaround time of 1 to 2 weeks. When you order the PCI-6230 with us, you can request basic (unaccredited) in-house calibration that will calibrate the part to the manufacturer specifications prior to being shipped. Call or email us today for more information about calibrating the PCI-6230!

Made By National Instruments
Part Number 779615-01
Analog Inputs 8 SE Ch (Single Ended Channels) or 4 Differential, 16 bit resolution, Input ranges: n10 V, n5 V, n1 V, n0.2 V
Analog Outputs 4 AO (Analog Outputs), 16-bit DAC, Output range: n10 V, Max update rate: 500 kS/s
Digital I/O 5V TTL, 6 Inputs, 4 Outputs
Isolation Bank isolation up to 60 VDC, Channel-to-bus isolation up to 1950 VDC

Distribution Cache Shipping Info and Options

Shipping Carriers: Here at Distribution Cache we ship using UPS, FedEx, DHL, or TNT. In most cases we get very competitive rates based on our volume and will be happy quote shipping cost to your location upon request. We also know that many customers would prefer to ship collect on their own account numbers and welcome this option.

Shipping Blind: We recognize that many of our customers intend to re-sell the product to their end user. We respect our customer’s relationships with their clients and offer blind shipping as an option to ensure that the package arrives in the most clandestine way possible.

Shipping Process: We take pride in the way we package your order and spare no cost in making sure that it arrives safely at your facility. In the case of new parts, we are always sure to package the factory box inside another larger box for safe transit. For reconditioned parts we often use Distribution Cache customized packaging that is specially made to protect the products from the bumps and falls present during shipment.

 

Shipping Options:

Next Day Air Early AM - This service is the fastest overnight delivery option available. For most locations the package will be guaranteed by 8:30AM.

Next Day Air – This service guarantees delivery by 10:30AM and is the most frequently used option for overnight shipments.

Next Day Air Saver – This cost saving overnight alternative guarantees delivery by 3PM the next day.

2nd Day Air – For domestic shipments that would take 3-5 days if shipped via Ground, sometimes having the order in 2 days is a great way to go

Ground – Ground is the most inexpensive shipping option provided. Please ask if we are doing a “free domestic ground” shipping promotion on your order. We often provide free ground shipping on larger orders.

 

Emergency Courier – At times we can help work with a courier service to get the part to your facility during downtimes scenarios. We prefer that the customer sets up the courier but we can be there to make sure the product is handed off to the driver. Please give us a call to see if this is an option on your order.

Please Note: Products listed as “ships today” can ship same-day if an order is placed before 4PM. For larger drives and motors we ask that notification for same-day shipments be provided by 2PM at the latest. For any products listed as “ships in 3-5 days”, please give us a call to see if this can be expedited.

Question:

What is the model number and the main functionality of the product offered by National Instruments?

Answer:

The product offered by National Instruments is the model 779615-01 PCI-6230, which is a multifunction data acquisition (DAQ) board from the M Series focused on providing bank isolation, high-performance amplification, timing, and calibration for accurate control and measurements.

Question:

How many analog output channels does the NI PCI-6230 have, and what is the maximum update rate per channel?

Answer:

The NI PCI-6230 has four analog output channels and the maximum update rate per analog output channel is 500 kS/s (kilo-samples per second).

Question:

What type of driver software is used to operate the NI PCI-6230, and what are some ADEs it is compatible with?

Answer:

The NI PCI-6230 is operated using the NIDAQmx driver software and is compatible with application development environments such as LabVIEW or LabWindows/CVI.

Question:

What is the physical weight and dimensions of the NI PCI-6230, and what is its operating temperature range?

Answer:

The NI PCI-6230 weighs 0.24 lb and measures 3.8 x 6.1 inches. Its recommended operating temperature range is from 0 to 55 degrees Celsius (0C).

Question:

What calibration options are available for the PCI-6230, and how often should it be calibrated?

Answer:

The PCI-6230 is available to be calibrated by Apex Waves, which offers high-quality NIST accredited calibrations through a 3rd party with an average turnaround time of 1 to 2 weeks. It also offers basic (unaccredited) in-house calibration to the manufacturer's specifications. It is recommended that most parts, likely including the PCI-6230, be calibrated either annually or every two years to ensure accuracy.