151831A-01L
National Instruments
151831A-01L
National Instruments

Description
The 151831A-01L NI TB-2630B is a front-mountable terminal block designed for the NI PXI-2530B multiplexer switch module, providing various configuration options for setups including shielding for high electrical noise environments. Please note, this terminal block is only compatible with the PXI-2530B and cannot be used with the PXI-2530.
The 151831A-01L NI TB-2630B is a front-mountable terminal block designed specifically for use with the NI PXI-2530B multiplexer switch module. This terminal block allows for various configurations of the switch module, including independent, 1-wire 128 x 1 multiplexer, dual 64 x 1 multiplexer, quad 32 x 1 multiplexer, octal 16 x 1 multiplexer, dual 16 x 1 multiplexer, 32 x 1 multiplexer, 64 x 1 multiplexer, dual 32 x 1 multiplexer, and quad 16 x 1 multiplexer setups. The NI TB-2630B terminal block features shielding, making it ideal for use in high electrical noise environments and ensuring compliance with EMF specifications. It includes ribbon cable headers for signal connections to the switch, but it is important to note that it is only compatible with the PXI-2530B and cannot be used with the PXI-2530.
Made By | National Instruments |
---|---|
Part Number | 151831A-01L / 781687-01 |
Compatible With | NI PXI-2530B Switch Module |
Mounting Type | Front-Mountable |
Multiplexer Configurations | Independent; 1-wire 128x1, dual 64x1, quad 32x1, octal 16x1; 4-wire dual 16x1, 32x1; 2-wire 64x1, dual 32x1, quad 16x1 |
Shielding | Yes, for use in high electrical noise areas and compliance with EMF specifications |
Distribution Cache Shipping Info and Options
Shipping Carriers: Here at Distribution Cache we ship using UPS, FedEx, DHL, or TNT. In most cases we get very competitive rates based on our volume and will be happy quote shipping cost to your location upon request. We also know that many customers would prefer to ship collect on their own account numbers and welcome this option.
Shipping Blind: We recognize that many of our customers intend to re-sell the product to their end user. We respect our customer’s relationships with their clients and offer blind shipping as an option to ensure that the package arrives in the most clandestine way possible.
Shipping Process: We take pride in the way we package your order and spare no cost in making sure that it arrives safely at your facility. In the case of new parts, we are always sure to package the factory box inside another larger box for safe transit. For reconditioned parts we often use Distribution Cache customized packaging that is specially made to protect the products from the bumps and falls present during shipment.
Shipping Options:
Next Day Air Early AM - This service is the fastest overnight delivery option available. For most locations the package will be guaranteed by 8:30AM.
Next Day Air – This service guarantees delivery by 10:30AM and is the most frequently used option for overnight shipments.
Next Day Air Saver – This cost saving overnight alternative guarantees delivery by 3PM the next day.
2nd Day Air – For domestic shipments that would take 3-5 days if shipped via Ground, sometimes having the order in 2 days is a great way to go
Ground – Ground is the most inexpensive shipping option provided. Please ask if we are doing a “free domestic ground” shipping promotion on your order. We often provide free ground shipping on larger orders.
Emergency Courier – At times we can help work with a courier service to get the part to your facility during downtimes scenarios. We prefer that the customer sets up the courier but we can be there to make sure the product is handed off to the driver. Please give us a call to see if this is an option on your order.
Please Note: Products listed as “ships today” can ship same-day if an order is placed before 4PM. For larger drives and motors we ask that notification for same-day shipments be provided by 2PM at the latest. For any products listed as “ships in 3-5 days”, please give us a call to see if this can be expedited.
Question:
What is the model number of the National Instruments terminal block designed for use with the NI PXI-2530B multiplexer switch module?
Answer:
The model number of the National Instruments terminal block is 151831A-01L, also known as the NI TB-2630B.
Question:
What kind of configurations can the 151831A-01L NI TB-2630B terminal block support?
Answer:
The 151831A-01L NI TB-2630B terminal block can support various configurations including independent, 1-wire 128 x 1 multiplexer, dual 64 x 1 multiplexer, quad 32 x 1 multiplexer, octal 16 x 1 multiplexer, dual 16 x 1 multiplexer, 32 x 1 multiplexer, 64 x 1 multiplexer, dual 32 x 1 multiplexer, and quad 16 x 1 multiplexer setups.
Question:
Why is the NI TB-2630B terminal block considered ideal for high electrical noise environments?
Answer:
The NI TB-2630B terminal block is considered ideal for high electrical noise environments because it features shielding, which ensures compliance with EMF specifications.
Question:
What type of cable headers does the 151831A-01L NI TB-2630B terminal block include for signal connections?
Answer:
The 151831A-01L NI TB-2630B terminal block includes ribbon cable headers for signal connections to the switch module.
Question:
Can the 151831A-01L NI TB-2630B terminal block be used with the PXI-2530?
Answer:
No, the 151831A-01L NI TB-2630B terminal block is only compatible with the PXI-2530B and cannot be used with the PXI-2530.